Joulescope-ui

Latest version: v1.1.9

Safety actively analyzes 631274 Python packages for vulnerabilities to keep your Python projects secure.

Scan your dependencies

Page 14 of 18

0.6.8

2019 Oct 15

* Fixed data-dependent single NaN sample insertion. Only occurred when
i_range was 3 or 7 and current LSBs was saturated.
Affects 0.6.0 through 0.6.7.
* Added customizable current range switching filter available through
File → Preferences → Current Ranging.
* Changed default current range switch filter from mean_0_3_1 to mean_1_n_1,
which significantly reduces the displayed glitches on current ranging.
If you like the old behavior, File → Preferences → Current Ranging to
set type: mean, samples_pre: 0, samples_window: 3, samples_post: 1.
The drawback is that up to 8 samples (4 µs) of data can be filtered out.

0.6.6

2019 Oct 9

* Fixed configuration to work on new installations (error introduced in 0.6.5).

0.6.5

2019 Oct 9

* Converted JSON5 config_def to python to improve start time.
* Updated to latest pyqtgraph.
* Improved waveform performance by only updating curve fill when needed.

0.6.4

2019 Oct 3

* Added NaN checks in multimeter when accumulating (Issue 2).
* Added configurable stream buffer duration (was fixed at 30 seconds).
* Added general-purpose input (GPI) support.
* Only update oscilloscope when visible (improve performance).

0.6.3

2019 Sep 22

* Only display mean for signal markers when zoomed to single sample.

0.6.2

2019 Sep 20

* Fixed log warning for on_fps_timer.
* Fixed error that prevented "Export data" on open JLS file.
* Sign macOS distribution and application.

Page 14 of 18